| |
TECHNICAL
INFORMATION
- The Company consists of 5-10 performers
and personnel:
- 2-4 dancers, 2-4 musicians, 1
production/lighting director and/or 1 company
manager
|
STAGE DIMENSIONS &
FLOOR
- A minimum performance area of 25' (8
meters) deep, 35' (12 meters) wide and 21' (7 meters) high
- Sprung wood floor, level and free from
obstacles. Concrete Floors are not
acceptable
|
LIGHTING
- 2 color stage wash capability from
front of house positions
- 3 or 4 overhead electric’s
- 8 12' booms for side lighting positions
to accommodate 4 units per boom
- Minimum 60 at 2.4k dimmers
- 1 programmable/memory lighting control
console
|
APPROXIMATE NUMBERS OF
SPECIFIC TYPE UNITS
- 10 20º beam spread Leko / Profile
w/shutters
- 50 30º beam spread Leko / Profile
w/shutters
- 50 40º beam spread Leko / Profile
w/shutters
- 35 Fresnel and/or Par 64 wide flood
- Sufficient lights for 2-3 color
cyclorama wash
- Sufficient cable to circuit light-plot
and sufficient ladders or lifts to focus
light-plot
|
FRONT OF HOUSE SOUND
SYSTEM
- 2 main speakers
- 1 subwoofer
- 2 1/3 oct. graphic EQ. If mono center
cluster: 1 separate 1/3 oct. EQ.
- 1 Stereo compressor
- Power should be 4 watts per channel per
audience member of venues full capacity
|
HOUSE MIXER &
OUTBOARD
- 24 channel mixing console with 2
monitor sends, 1-2 effect sends, 3 band EQ. (w/sweepable mids),
Phase shift capability, 48v phantom per channel
- Minimum of 4 submasters with insert
points
- 4 compressors
- 2 reverb units
- 1 CD playback deck (pre show
music)
|
MONITOR MIXER &
OUTBOARD
- 16 Channel monitor mixing console with
minimum 3 pre-fade mixes, located off-stage left
- 3 1/3 oct. EQ
- 4 sidefills (1x15" &
1x2")
- 2 wedges (1x12" & 1x1")
- 1 wedge for monitor mixer position
- Power should be 2 watts per channel per
audience member of venues full capacity
|
MICROPHONES
- 3 Crown PCC 160
- 2 AKG 451
- 4 Shure SM 57 and/or 58 used as back-up
only for company owned wireless system
- Please ask for additional sound set-up
page for imput list and notes on configuration
|
HEADSETS
- Communication needs from stage manager
to all various crew positions during performance; to include
light board op., sound board op., stage left and stage right
positions and from audience seating area to all various crew
positions during rehearsals
|
SOFTGOODS
- Velour or duvetyn legs and borders with
at least 2 entrances on each side of stage
- 1 white or sky blue cyclorama
- 1 black sharkstooth
scrim
|
PROPS
- 6 wooden, sturdy, armless and visually
similar, straight-backed chairs to be used on stage during
performance
|
DRESSING
ROOMS
- 3 dressing rooms with mirrors, clothing
racks, tables and chairs
- Dressing room assignments will be made
by company at time of load-in
- If possible, dressing rooms should be
located on stage level
- Bottled, non-carbonated water with cups
and snacks during rehearsals and performances
|
WARDROBE
- 1 steamer and iron w/ironing board
- 1 Experienced wardrobe crew person
- Sufficient space and tables needed to
steam and iron flamenco dresses
|
TEMPERATURE
- A minimum of 70º F (21º C)
must be maintained on stage and in all dressing rooms when
company is present in the theater facility
|
TECHNICAL
CREW
- The sponsor must provide experienced
crew for load-in, rehearsals, performances and load-out of the
company. The exact size of those crew calls shall be determined
by the company's production manager and the production manager
of the theater
- Assuming there is a pre-hung, circuited
lighting plot and softgoods, a typical breakdown would be:
6 HOURS LOAD-IN /
FOCUS LIGHTING
4 electricians, 2 sound
technicians, 1 wardrobe person
4 HOURS SOUND CHECK AND DRESS REHEARSAL
2 stagehands, 1 sound board operator, 1
additional sound person for sound checks preferably Spanish
speaking, 1 light Board operator, 1 wardrobe person
4 HOURS
PERFORMANCE
2 stagehands, 2 sound board
operators, 1 light Board operator, 1 wardrobe
person
|